Submersible direct-drive progressing cavity pump rodless lifting technology
|
HAO Zhongxian,ZHU Shijia,PEI Xiaohan,HUANG Peng,TONG Zheng,WANG Benyuan,LI Deyin
|
|
|
Table 1 Comparison of operating parameters of ESPCP and previous pumping unit.
|
|
Unit | Installed power/kW | Daily liquid production/t | Daily power con- sumption/(kW·h) | Active power/kW | Reactive power/kW | Power factor | System efficiency/% | Pump efficiency/% | Pumping unit | 22 | 24.9 | 233.23 | 9.11 | 20.3 | 0.409 | 31.50 | 56.98 | ESPCP | 12 | 24.5 | 138.20 | 5.77 | 0 | 0.998 | 39.49 | 81.95 |
|
|
|