Technologies and practice of CO2 flooding and sequestration in China
HU Yongle,HAO Mingqiang,CHEN Guoli,SUN Ruiyan,LI Shi
Table 5 CO2 flooding tests in the Jilin Oilfield.
Block Reservoir type Permea-
bility/
10-3 μm2
Well pattern Reserves/
104 t
Number of
injectors and
producers
Cumulative CO2 injected/104 t HC pore volume multiple of injected CO2 Annual oil
production
capacity/104 t
Hei-59 CO2 flooding in
original oil reservoir
3.5 140 m×440 m, inverted-seven-spot 102 6 injectors,
25 producers
27.3 0.330 2.6
Expanded test in
Hei-79 South
Converting to CO2 flooding at mid-high water cut 19.8 160 m×480 m, inverted-nine-spot
inverted-seven-spot
240 18 injectors,
60 producers
41.2 0.210 5.1
Short well
spacing test in
Hei-79 North
Converting to CO2 flooding at super-
high water cut
4.5 80 m×240 m, inverted-seven-spot 108 10 injectors,
27 producers
17.8 0.550 1.2
Large-scale
application
test in Hei-46
Large-scale
application test
4.8 150 m×600 m,
212 m×424 m, inverted-nine-spot
671 26 injectors,
139 producers
32.6 0.076 4.4