Colloidal gas aphron (CGA) based foam cement system
|
VELAYATI Arian,ROOSTAEI Morteza,RASOOLIMANESH Rasool,SOLEYMANI Mohammad,FATTAHPOUR Vahidoddin
|
|
|
Table 2 Results of physical property tests on foamed cement (slurries).
|
|
Cement (slurry) formulation | Cement slurry recipe | Water to cement ratio | Foam volume fraction/% | Density/ (kg·m-3) | Free water content/% | Poro- sity/% | Permea- bility/ 10-3 μm2 | Elastic modulus/ GPa | Poisson’s ratio | Compressive strength/kPa | Foam stability | Volume Reduction rate under 3445 kPa pressure/% | 1 | 1 | 0.44 | 10 | 1728 | 0.4 | 29 | 0.40 | 4.00 | 0.12 | 14056 | Ok | 2 | 2 | 1 | 1.00 | 20 | 1232 | 10.0 | 43 | 11.58 | 1.56 | 0.13 | 1860 | Ok | 5 | 3 | 2 | 1.00 | 10 | 1168 | 10.0 | 34 | 4.85 | 1.60 | 0.12 | 2081 | Ok | --- | 4 | 3 | 1.00 | 10 | 1040 | 0 | 24 | 0.70 | 1.12 | 0.15 | 4823 | Very Good | --- |
|
|
|