Forward simulation of array laterolog resistivity in anisotropic formation and its application
YUAN Chao,LI Chaoliu,ZHOU Cancan,XIAO Qiyao,LI Xia,FAN Yiren,YU Jun,WANG Lei,XING Tao
Table 1 Error analysis between the results from experimental measurement and numerical simulation.
Relative
dip angle
Measuring resistivity Experimental
measurement/(Ω•m)
Numerical simulation/(Ω•m) Error/
%
α=0° RLA1 38.94 37.278 4.50
RLA2 36.75 35.750 2.80
RLA3 34.78 34.670 0.30
RLA4 33.34 33.690 1.00
RLA5 30.96 31.380 1.30
α=60° RLA1 14.36 15.36 6.50
RLA2 14.87 15.63 4.90
RLA3 15.60 15.62 0.10
RLA4 16.17 15.51 4.20
RLA5 15.93 14.88 7.10