Forward simulation of array laterolog resistivity in anisotropic formation and its application
|
YUAN Chao,LI Chaoliu,ZHOU Cancan,XIAO Qiyao,LI Xia,FAN Yiren,YU Jun,WANG Lei,XING Tao
|
|
|
Table 1 Error analysis between the results from experimental measurement and numerical simulation.
|
|
Relative dip angle | Measuring resistivity | Experimental measurement/(Ω•m) | Numerical simulation/(Ω•m) | Error/ % | α=0° | RLA1 | 38.94 | 37.278 | 4.50 | RLA2 | 36.75 | 35.750 | 2.80 | RLA3 | 34.78 | 34.670 | 0.30 | RLA4 | 33.34 | 33.690 | 1.00 | RLA5 | 30.96 | 31.380 | 1.30 | α=60° | RLA1 | 14.36 | 15.36 | 6.50 | RLA2 | 14.87 | 15.63 | 4.90 | RLA3 | 15.60 | 15.62 | 0.10 | RLA4 | 16.17 | 15.51 | 4.20 | RLA5 | 15.93 | 14.88 | 7.10 |
|
|
|