Structural failure mechanism and strengthening method of fracture plugging zone for lost circulation control in deep naturally fractured reservoirs
|
XU Chengyuan,YAN Xiaopeng,KANG Yili,YOU Lijun,ZHANG Jingyi
|
|
|
Table 2 Basic parameters of the model.
|
|
Parameter | Value | Parameter | Value | Particle size distribution D90 | 0.5 mm | Fiber tensile strength | 35 MPa | Fiber aspect ratio | 50 | Fiber concentration | 4% | Friction angle of particle surface | 36° | Fracture closure pressure | 10 MPa | Friction angle of fiber surface | 24° | Plugging zone porosity | 15% | Friction angle between plugg- ing zone and fracture surface | 45° | Plugging zone length | 15 mm | Elastic modulus of fiber | 20 MPa | Fracture width | 1 mm |
|
|
|