Structural failure mechanism and strengthening method of fracture plugging zone for lost circulation control in deep naturally fractured reservoirs
|
|
XU Chengyuan,YAN Xiaopeng,KANG Yili,YOU Lijun,ZHANG Jingyi
|
|
| |
Table 3 Performance parameters of some LCMs used in the fracture plugging experiment.
|
|
| No. | Initial D90/μm | Friction coefficient | D90 degradation rate after compression/% | D90 degradation rate after aging and compression/% | | K3 | 7836 | 1.23 | 8.76 | 4.20 | | K4 | 4207 | 0.95 | 17.66 | 6.50 | | K5 | 2715 | 1.07 | 17.66 | 4.01 | | G7 | 3801 | 0.89 | 4.78 | 1.02 | | G12 | 4797 | 0.66 | 3.84 | 1.14 | | D2 | 4380 | 0.94 | 4.48 | 1.39 | | D11 | 1155 | 1.04 | 2.12 | 8.72 |
|
|
|